Specifications:
- Application Indoor
- Antenna Interface 7-16 DIN Female
- BTS Interface 7-16 DIN Female
- Color Black | Copper
- Rack Type EIA 19 in
- Rack Units 2
- Rx Interface N Female
- Rx2 Interface SMA Female
- Height 88.1 mm | 3.469 in
- Width 482.6 mm | 19 in
- Depth 377.6 mm | 14.866 in
- 3rd Order IMD Test Method Two +43 dBm carriers
- 3rd Order IMD, maximum -150 dBc
- dc Interface SMA Female
- dc Pass-through Rx
- License Band Cellular
- Band Rejection at Operating Frequency 27 dB @ 800–814 MHz | 30 dB @ 851–869 MHz | 50 dB @ 700–800 MHz | 50 dB @ 960–6000 MHz
- Bandwidth 25 MHz
- Frequency Band 824 – 849 MHz
- Group Delay Variation at Frequency, maximum 75 ns @ 1.23 MHz | 150 ns @ 5.00 MHz
- Insertion Loss, maximum 1.8 dB
- Insertion Loss, typical 0.5 dB
- Return Loss, minimum 18 dB
- Total Group Delay, maximum 280 ns
- Tx Band Rejection 80 dB
- Bandwidth 25 MHz
- Frequency Band 824 – 849 MHz
- Group Delay Variation at Frequency, maximum 40 ns @ 1.23 MHz | 80 ns @ 5.00 MHz
- Total Group Delay, maximum 150 ns
- Tx Band Rejection 80 dB
- Insertion Loss, maximum 1 dB
- Insertion Loss, typical 0.8 dB
- Return Loss, minimum 18 dB
- Band Rejection at Operating Frequency 20 dB @ 896–902 MHz
- Bandwidth 25 MHz
- Frequency Band 869 – 894 MHz
- Group Delay Variation at Frequency, maximum 50 ns @ 1.23 MHz | 100 ns @ 5.00 MHz
- Input Power, PEP, maximum 12000 W
- Input Power, RMS, maximum 800 W
- Rx Band Rejection 80 dB
- Total Group Delay, maximum 200 ns
- Insertion Loss, maximum 0.9 dB
- Insertion Loss, typical 0.4 dB
- Return Loss, minimum 18 dB